CİHAZ SATIŞI

Render Koter

Render Koter Render Koter
  • AÇIKLAMA
Koter Cihazı Özellikleri -With high performance neutral electrode contact inspection system,system will test and evaluate the effective contact area between electrode and derma, if the contact area was found low to a danger level, system will automatic cutout and gives alarm indication.

-Owns memory function, reserves the last time used data.

-High definition large LED indication.

-Main unit has automatic monitoring function and mistake indication function.

-Automatic compensation function stabilize output power, make depletion to its lowest.

-Can cut underwater, including organic cut in rich fat area.

Technical Parameters:

a) Ambient temp. range: 5ºC?40 ºC?

b) Relative Humidity Range: ?80?

c) Atmospheric Pressure Range: 86.0?106.0kpa? d) Power: 220V±22V?50Hz±1?

e) Operating Freq.: 330?460kHz; f) Rated Power: 1100VA±10%?

g) Type: CF

Power Consumption:

?1100VA (Cut function 400)

Six output mode:

a) Cut: 400W b) Blend 1: 250W

c) Blend 2: 200W e) Electro Coag 1: 100W

f) Electro Coag 2: 80W h) Bipolar Coag: 50W

Power: 220V±22V?50Hz±1Hz

Application:Applicable for general surgery, thoracic surgery, orthopedics, obstetrics and gynecology, urologic surgery, cerebral surgery, microsurgery, ENT surgery and etc.

-Cut: Pure cut, can make easy operation for any organic, tissue, texture, the effect is refine cut, no escharosis on the surface.

-Blend 1: The effect is cut with tiny coagulation;

-Blend 2: Can use this function together with Endoscope, the effect is offering a better coagulation during cut;

-Electro Coag 1: Called strength electrocoagulation, or called surface coagulation, for a deep coagulation layer for organic.

-Electro Coag 2: Called soft electrocoagulation, or called Point coagulation, faster coagulation, larger effect area?

Can use this function together with Endoscope;

-Bipolar Coag: Called rapid Bipolar coagulation, to provide coagulation function rapidly at boot,which can prevent organic's adhesion.

Transportation and Storage:

a) Ambient Temp. Range: -40 ºC ? 55 ºC?

b) Relative Humidity: ?95%?

c) Atmospheric Pressure: 500hpa ? 1060hpa?

Product Size: 365mm (L) x 330mm (W) x 125mm (H)

Weight: N.W. 6.5 KG, G.W.10.5 KG

Packing size: 46 x 42 x 30 cm

Standard Configuration

a) Main unit: 1 pc

b) Double footswith: 1 pc

c) ESU pencil: 2 pcs

d) Electrode (Disposable): 2 pcs

e) Bipolar forceps: 1 pc

f) Bipolar forceps cable: 1 pc

g) Electrode cable: 1 pc

h) Power cable: 1 pc

j) User's manual: 1 pc

k) Packing List: 1 pc

l) Guarantee card: 1 pc